Schedule Appointment

Recent Project: Burnet | Lakevista | Metal Roofing | 09-30-25 | APS-4501

24-Gauge Galvalume Standing Seam Metal Roof Installation | Vented Ridge Snap Lock System With High-Temp Underlayment

Schedule a Free Siding Inspection
Schedule Your Free Siding Estimate
A+ BBB Accolade
4.9 Rating

wHAT wE DID

Metal Roofing

This Burnet metal roofing project used a 24-gauge Galvalume standing seam roof with a 1.5-inch snap lock panel. We paired the panels with hidden clips, high-temp Epilay underlayment, and a vented Z ridge for airflow. Standing seam holds up far better than shingles against Central Texas hail and 100-degree summers. The homeowner ended up with a sealed, vented, insurance-backed roof finished in one day.

Learn More About Our Siding
How It works

The Journey

01
02
03
04
05

First Contact

Our salesman met the homeowner while canvassing the Lakevista area of Burnet on May 8, 2025. A recent storm had left roof damage worth filing an insurance claim, and that first-contact conversation turned the lead into a prospect the same day.

Evaluation

We inspected the existing roof and confirmed storm damage that supported an insurance claim. The assessment pointed to a full replacement rather than a patch, given how hard Central Texas hail is on asphalt shingles.

PLanning & Approval

The homeowner selected a 24-gauge Galvalume standing seam system with a 1.5-inch snap lock profile. Working through the insurance claim, the project was approved on May 22, 2025, with McElroy Metal Sure Lock panels specified for the job.

Installation

On September 30, 2025, the crew led by Jose Rangel completed the full tear-off and metal install in a single day. They laid Epilay Ultra high-temp underlayment, set eave and rake drip edge, installed the clip-fastened panels, and finished with a vented Z ridge and Galvalume ridge cap. ABC Supply delivered the metal and G&J Seamless Rain Gutters handled the drainage tie-in.

Completion

We walked the finished roof the same day, confirming sealed seams and a fully vented ridge. The job was invoiced on September 30 and closed on October 2, 2025, leaving the homeowner with an insurance-backed, low-maintenance metal roof.

Metal Roofing in Lakevista, Burnet | Austin Pro

We tore off and replaced a storm-damaged roof in Burnet, TX with a 24-gauge Galvalume standing seam metal system, finishing the full job in a single day on September 30, 2025. The home now carries a clip-fastened, fully vented roof built for Hill Country weather.

Project at a glance

  • Service: Metal roofing tear-off and replacement
  • Location: Lakevista, Burnet, TX (78611)
  • Vendor & product: McElroy Metal Sure Lock 24-gauge Galvalume standing seam
  • Material: 1.5-inch snap lock panel, roughly 16.5-inch pan from 21-inch coil
  • Timeframe: Approved May 22, 2025; installed and invoiced September 30, 2025
  • Standout outcome: A vented, hail-ready roof installed in one day through an insurance claim

Why did this Burnet home need a new roof?

A storm rolled through and left enough damage to open an insurance claim. Our salesman first met the homeowner while canvassing the Lakevista area on May 8, 2025.

That single visit turned into a full roof replacement. Here's what drove the decision:

  • Work type was filed as an insurance claim, not out-of-pocket
  • Central Texas hail is hard on asphalt shingles, which bruise and lose granules
  • The homeowner wanted a roof that would outlast the next few storm seasons
  • Burnet's 100-degree summers punish dark shingles year after year

What did we choose for the roof, and why?

We went with a 24-gauge Galvalume standing seam system for its strength and clean look. Galvalume is a steel coated with aluminum and zinc, and that blend fights corrosion far longer than plain galvanized steel.

The real advantage here is the standing seam profile itself. The 1.5-inch snap lock panels lock together over hidden clips, so there are no screws punched through the face of the roof. Those exposed fasteners are usually the first thing to fail on cheaper metal roofs, because the rubber washers dry out and leak under Hill Country heat. By hiding the clips instead, the panels can expand and shift as the roof heats past 100 degrees without tearing at the fastener. Fewer holes in the field means fewer places for water to ever find its way in.

  • 24 GA Galvalume coil, cut to a 16.5-inch pan for even panel spacing
  • Double lock 1.5-inch clips that let panels move with heat
  • Deck Tite and Deck Tite sealants at penetrations
  • Rivets, screws, and plastic caps for a tight, finished assembly

How did we handle the underlayment and ventilation?

A metal roof is only as good as what sits under it, so we laid a high-temp synthetic underlayment across the deck. We also built a vented ridge to let hot attic air escape.

Good airflow matters more here than most homeowners think. Under a metal roof in a Burnet summer, trapped attic heat cooks a home from the top down and drives up cooling bills. The details we used:

  • Epilay Ultra high-temp underlayment, rated for metal roof heat
  • Vented Z closure at the ridge, sized to the 1.5-inch rib
  • Galvalume ridge cap over the vent for a clean, weather-tight line
  • Matching eave and rake drip edge to shed water off the edges

How did the installation go?

The crew, led by Jose Rangel, completed the tear-off and full metal install in one day. Metal supply came in through ABC Supply, and G&J Seamless Rain Gutters handled the drainage tie-in.

  • Panels delivered and staged on site the morning of install
  • Full eave and rake drip edge set before the field panels
  • Caulk and sealant run at every seam and penetration
  • Job invoiced same day, September 30, 2025, and closed October 2

What did the homeowner end up with?

The finished roof is a sealed, vented, corrosion-resistant system that should outlast any shingle roof in the neighborhood. It sheds hail impact, reflects summer heat, and needs almost no upkeep beyond an occasional gutter cleaning after cedar pollen season.

  • A standing seam roof with no exposed field fasteners
  • Full ridge ventilation for a cooler attic
  • An insurance-backed replacement handled start to finish
  • A finish that pairs well with future gutters or exterior updates

Frequently asked questions

How long does a metal roof last in Central Texas?

A well-installed 24-gauge Galvalume standing seam roof commonly lasts 40 to 50 years. The hidden-clip design and high-temp underlayment are what carry it through decades of Burnet heat and hail.

Why choose standing seam over exposed-fastener metal?

Standing seam hides the clips under the panels, so no screws pierce the roof's face. That removes the most common leak point and lets the metal expand freely when temperatures climb past 100 degrees.

What did this metal roof cost?

This project fell in the $25,000 to $30,000 range and was covered as an insurance claim. Cost varies with roof size, pitch, and how many penetrations need flashing.

How long did the whole project take?

From the first canvassing visit on May 8 to approval on May 22, the timeline moved quickly. The actual install was a single day on September 30, 2025.

GAF shingle roofGAF Master Elite Certificate
No items found.